The contents of this page may be found at https://www.mecerlaptops.co.za. The contents are copyright. Although every effort has been made to ensure the accuracy of information, no reliance may be placed on the accuracy of the contents or any price found on this site. Any and all information should be used for reference purposes only. This site is neither owned nor operated by Mecer™©, but it is offered as an extension to laptopdirect.co.za as a reseller service to the public. We hold no claim whatsoever to the brand/s, logo/s or any other property or rights owned by Mecer™©. The information and pricing may have been valid prior to this page being captured, however, a print is not a valid advertisement for pricing nor specifications, and only products that have been sent by quote are valid. Prices are subject to change without prior notice. T&C's apply.

ME-10K-GA33

Mecer Galleon II 3P/3P 10K / Online Tower 3 phase UPS PF1.0

Mecer - Mecer Galleon II 3P/3P 10K / Online Tower 3 phase UPS PF1.0, 3-phase in / 3-phase out, Up to 6 units in parallel, Zero transfer time Inverter to bypass, Pure Sine Wave, 9 hours recover to 90% capacity typical recharge time, 12v/9ah battery Type
BUY TODAY ! Expected to be in Stock at suppliers.* print


Not rated yet



Rate this product

Prices, images and descriptions are for reference purposes only & may change without prior notice. PLEASE RELY ON ABOVE DESCRIPTIONS AND NOT ON IMAGES. ME-10K-GA33 Mecer Galleon II 3P/3P 10K / Online Tower 3 phase UPS PF1.0 is available from Mecer Laptops and it is sold as new from our Inverters range of products. For reference purposes, the price of R33780 is valid 2022-08-14, and while stocks last, may be valid until . The price displayed is a guide for reference purposes only, and may change without prior notice. Reference prices are an invitation for potential buyers to make an offer to purchase, which we may reject without reason. A quote with final pricing is sent before a purchase can be made. T&C's apply. E&OE. Laptop Direct. You are looking at products found in the Inverters category.
Subscribe

Specification for the entire series

Important information: Kindly note that specifications differ between models. Features, options and accessories displayed below this paragraph are not included with this product unless it has been specified in the above description.


Please remember these important points when reading the information below this paragraph: Operating systems cannot be removed or changed, monitors are not included with computers, free Anti-virus and Office Software are trial versions or may have limited features and an additional license needs to be purchased to activate the full product.

ME-10K-GA33

Mecer Galleon II 3P/3P 10K / Online Tower 3 phase UPS PF1.0

Mecer Galleon II 3P/3P 10K / Online Tower 3 phase UPS PF1.0, 3-phase in / 3-phase out, Up to 6 units in parallel, Zero transfer time Inverter to bypass, Pure Sine Wave, 9 hours recover to 90% capacity typical recharge time, 12v/9ah battery Type

Overview:

Galleon II 3P/3P 10K-80K PF1, three-level inverter, common battery
Galleon II 3P/3P 10K-80K provides better output power factor up to 1.0 with higher performance and efficiency for critical applications. Its same as Galleon series with programmable power management outlets which can extend available battery time to critical devices by shutting down unnecessary devices. This Galleon II 3P/3P 10K-80K series is also suitable for laser printer and ultrasound system load.

Features:

  • True double-conversion
  • DSP technology guarantees high reliability
  • Output power factor 1.0
  • Active power factor correction in all phases
  • 50hz/60hz frequency converter mode
  • ECO mode operation for energy saving
  • Emergency power off function (EPO)
  • Optional parallel operation
  • Smart battery charger design to optimize battery performance
  • Maintenance bypass available
  • Adjustable battery design


Specifications:

© 2022 Respective owners and brand holders. This table has been carefully researched and generated by Laptop Direct CC (https://www.laptopdirect.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered.
Specificationsspacer
Product CodeME-10K-GA33spacer
MODELGalleon II-3/3 10K(L)
CAPACITY10 KVA / 10 KW
PHASE3-phase in/3-phase out
PARALLEL CAPABILITYup to 6 units in parallel
INPUT
Voltage Range190 - 520 VAC (3-phase) @ 50% load, 305 - 478 VAC (3-phase) @ 100% load
Nominal Voltage3 x 380/ 400/ 415 VAC ( 3 Ph+N)
Frequency Range40~70 Hz
Power Factor>= 0.99 @ 100% load
OUTPUT
Output Voltage3 x 360*/380/400/415 (3 Ph +N)
AC Voltage Regulation (Batt. Mode)± 1%
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Transfer Time AC Mode to Battery Modezero
Transfer Time Inverter to Bypasszero
Waveform (Batt. Mode)Pure Sine Wave
Current Crest Ratio3:1 (max.)
Harmonic Distortion≦ 2 % THD (Linear Load), ≦ 5 % THD (Non-linear Load)
Frequency Range (Synchronized Range)46~54Hz or 56~64Hz
Overload AC Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
Overload Battery Mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
EFFICIENCY
Battery Mode96%
ECO Mode99%
AC Mode96%
BATTERY
Model-Battery TypeDepending on the capacity of external batteries
Model-Charging Current (max.)1A ~ 12A (Adjustable)
Model-Charging Voltage+/-136.5 VDC ± 10%
Model-Numbers(10+10) pcs
Battery Type12V/9Ah
Charging Current (max.)1A~12A (Adjustable)
Charging Voltage+/-136.5 VDC ± 10%
Numbers(10+10)pcs
Typical Recharge Time9 hours recover to 90% capacity
INDICATORS
LCD PanelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ENVIRONMENT
Operating Temperature0~40°C
Operating Humidity<95% and non-condersing
Noise LevelLess than 55dB @ 1 Meter
PHYSICAL
Standard Model Dimension, D X W X H (mm)630 x 250 x 826
Standard Model Net Weight (kgs)124
Long-run Model Dimension, D X W X H (mm)630 x 250 x 826
Long-run Model Net Weight (kgs)28
MANAGEMENT
Optional SNMPPower management from SNMP manager and web browser
Smart RS-232/USBSupports Windows 2000/2003/XP/Vista/2008, Windows 7 / / / 8 / / / 10, Linux, and MAC
, ©2022 Laptop Direct CC


Download: pdf_downloads/20/207391_PDF1.pdf (452702 KB)

Reviews ME-10K-GA33 Mecer Galleon II 3P/3P 10K / Online Tower 3 phase UPS PF1.0

Review
Do you have an opinion about this product? [+] Add your review

This product has not been rated yet.

Power in a box for loadshedding